• Sonel MIC-30 Insulation Resistance Meter

Insulation resistance measurement:

  • test voltage: 50...1000 V range with 10 V step,
  • automatic measurement in sockets with the UNI-Schuko adapter with possibility of configuring pairs of measured cables,
  • continuous indication of insulation resistance or leakage current,
  • automatic discharge of capacitance of tested object after the insulation resistance measurement,
  • acoustic signalling of five-second periods to facilitate obtaining time characteristics,
  • measured test times T 1 , T 2 i T 3 to measure one or two absorption coefficients in the 1... 600 sec. range,
  • indication of actual test voltage during the measurement,
  • protection against measuring live objects,
  • three-lead measurement.

Continuity measurement of protective and equipotential conductors according to EN 61557 - 4 with the >200 mA current

Low-voltage circuit continuity and resistance measurement:

  • circuit resistance measurement (<1999 Ω ) with the <15 mA current,
  • quick sound signal if circuit resistance is below 30Ω.

Leakage current measurement.

Capacitance measurement during the R ISO measurement

Measurement of alternating and direct voltages in the 0...600 V range.

990 memory cells and wireless data transmission to a computer using the USB - OR-1 adapted.

Power supply: 4 AA disposable or rechargeable batteries, monitoring of power supply voltage.

Meters conform to EN 61557.

Electric safety:

  • type of insulation: double, according to EN 61010 - 1 and IEC 61557
  • measurement category: IV 600 V (III 1000 V) according to EN 61010 - 1
  • protection class acc. to EN 60529: IP67

Other technical specifications:

  • power suply: 4 alkaline batteries or or battery package Ni-MH
  • weight: ~1 kg
  • dimentions: 220 x 100 x 60 mm

Insulation resistance measurement

Measuring range according to EN 61557 - 2 for U N =50 V : 50 kΩ...250,0 MΩ

Range Resolution Accuracy
0,0...999,9 kΩ 0,1 kΩ ±(3% m.v. + 8 digits)
[±(5% m.v. + 8 digits)]*
1,000...9,999 MΩ 0,001 MΩ
10,0...99,99 MΩ 0,01 MΩ
100,0...250,0 MΩ 0,1 MΩ

*for the WS-04 lead

Measuring range according to EN 61557 - 2 for U N =100 V : 100 kΩ...500,0 MΩ

Range Resolution Accuracy
0,0...999,9 kΩ 0,1 kΩ ±(3% m.v. + 8 digits)
[±(5% m.v. + 8 digits)]*
1, 000...9,999 MΩ 0,001 MΩ
10,0...99,99 MΩ 0,01 MΩ
100,0...500,0 MΩ 0,1 MΩ

*for the WS-04 lead

Measuring range according to EN 61557 - 2 for U N =250 V : 250 kΩ...2,000 GΩ

Range Resolution Accuracy
0,0...999,9 kΩ 0,1 kΩ ±(3% m.v. + 8 digits)
[±(5% m.v. + 8 digits)]*

1,000...9,999 MΩ

0,001 MΩ

10,0...99,99 MΩ

0,01 MΩ
100,0...999,0 MΩ 0,1 MΩ
1,000...2,000 GΩ 0,001 GΩ

*for the WS-04 lead

Measuring range according to PN-EN 61557 - 2 for U N =500 V : 500 kΩ...20,00 GΩ

Range Resolution Accuracy
0,0...999,9 kΩ 0,1 kΩ ±(3% m.v. + 8 digits)
[±(5% m.v. + 8 digits)]*
1,000...9,999 MΩ 0,001 MΩ
10,00...99,99 MΩ 0,01 MΩ
100,0...999,0 MΩ 0,1 MΩ
1,000...9,999 GΩ 0,001 GΩ ±(4% m.v. + 6 digits)
[±(6% m.v. + 6 digits)]*
10,00...20,00 GΩ** 0,01 GΩ

*for the WS-04 lead
**for the WS-04 lead range to 10 GΩ

Measuring range according to EN 61557 - 2 for U N =1000 V : 1000 kΩ...10,00 GΩ

Range Resolution Accuracy
0,0...999,9 kΩ 0,1 kΩ ±(3% m.v. + 8 digits)
1,000...9,999 MΩ 0,001 MΩ
10,00...99,99 MΩ 0,01 MΩ
100,0...999,0 MΩ 0,1 MΩ
1,000...9,999 GΩ 0,001 GΩ ±(4% m.v. + 6 digits)
10,00...99,99 GΩ 0,01 GΩ
100,0 GΩ 0,1 GΩ

Continuity measurement of protective and equipotential conductors with the 200 mA current

Measuring range according to EN 61557 - 4: 0,10...1999 Ω

Range Resolution Accuracy
0,00...19,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
20,0...199,9 Ω 0,1 Ω
200...1999 Ω 1 Ω

±(4% m.v. + 3 digits)

  • Voltage on open terminals: <8 V
  • Output current at R <2 Ω: I SC >200 mA: I SC >200 mA
  • Compensation of test leads’ resistance
  • Unidirectional current flow

Low-voltage and resistance measurement

Range Resolution Accuracy
0,0...199,9 Ω 0,1 Ω ±(3% m.v. + 3 digits)
200...1999 Ω 1 Ω
  • Voltage on open terminals: <8 V
  • Current for closed terminals 5 mA < ISC < 15 mA
  • Sound signal and green LED on when measured resistance < 30 Ω ± 50%
  • Compensation of test leads’ resistance,

Capacitance measurements

Range Resolution Accuracy
1...999 nF 1 nF ±(5% m.v. + 5 digits)
1,00...9,99µF 0,01µF
  • Capacitance value displayed during the R ISO measurement
  • For test voltages below 100 V and measured resistance below 10 MΩ, unspecified capacitance measurement error

Measurement of alternating and direct voltage

Range Resolution Accuracy
0,0...299,9 V 0,1 V ±(2% m.v. + 6 digits)
300...600 V 1 V ±(2% m.v. + 2 digits)

Frequency range: 45...65 Hz

Complete device information