Insulation resistance measurement: up to 5 TΩ
- measuring voltage: 50 ... 5000 V range (50 ... 500 V at 50 V step, and 500 V to 5000 at 100 V step),
- continuous indication of insulation resistance or leakage current,
- automatic discharge of capacitance of tested object after the insulation resistance measurement,
- acoustic signalling of five-second periods to facilitate obtaining time characteristics,
- measured test times of T1, T2 and T3 for measuring the absorption coefficient DAR and polarization index PI,
- indication of actual test voltage during the measurement,
- protection against measuring live objects.
Two and three-lead measurement method.
RampTest Insulation resistance measurement and measurement of breakdown voltage with increments up to ~ 1 kV / s.
Measurement of alternating and direct voltages in the 0...750 V range.
990 cells of memory (11880 records), data transmission to a PC through a USB cable.
Built-in rechargeable battery pack.
The instruments meet the requirements of the EN 61557 standard.
The ability to charge from car lighter (12 V) socket (additional accessories).
Insulation resistance measurement (two-lead)
Measurement range acc. toIEC 61557- 2 dla R
ISOmin
=U
ISOnom
/I
ISOmax
...1 TΩ (I
ISOmax
=1 mA)
Range | Resolution | Accuracy |
0,0...999,9 kΩ | 0,1 kΩ | ±(3% m.v. + 20 digits) |
1,000...9,999 MΩ | 0,001 MΩ | |
10,00...99,99 MΩ | 0,01 MΩ | |
100,0...999,9 MΩ | 0,1 MΩ | |
1,000...9,999 GΩ | 0,001 GΩ | |
10,00...99,99 GΩ | 0,01 GΩ | |
100,0...999,9 GΩ | 0,1 GΩ | |
1,000...5,000 TΩ | 1 GΩ | ±(4% m.v. + 50 digits) |
Values of measured resistance depending on measurement voltage
Voltage U ISO | Measurement range |
up to 100 V | 50 GΩ |
200...400 V | 100 GΩ |
500...900 V | 250 GΩ |
1000...2400 V | 500 GΩ |
2500 V | 1000 GΩ |
5000 V | 5 TΩ |
RampTest Insulation resistance measurement
Range | Resolution | Accuracy |
0,0...999,9 kΩ | 0,1 kΩ | ±(5% m.v. + 40 digits) |
1,000...9,999 MΩ | 0,001 MΩ | |
10,00...99,99 MΩ | 0,01 MΩ | |
100,0...999,9 MΩ | 0,1 MΩ | |
1,000...9,999 GΩ | 0,001 GΩ | |
10,00...99,99 GΩ | 0,01 GΩ | |
100,0...999,9 GΩ | 0,1 GΩ | |
1,000...4,999 TΩ | 0,001 TΩ |
The measurement of breakdown voltage in RampTest mode
Range | Resolution | Chosen U ISO | Accuracy |
25,0 V …99,0 V | 0,1 V | <600 V | ± 5% m.v. ± 10 digits |
100 V … 600 V | 1 V | <600 V | ± 5% m.v. ± 4 digits |
25 V … 999 V | 1 V | >600 V | ± 5% m.v. ± 5 digits |
1.00 kV … 5.00 kV | 10V | >600 V | ± 5% m.v. ± 4 digits |
DC and AC voltage measurement
Range | Resolution | Accuracy |
0...299,9 V | 0,1 V | ±(3% m.v. + 2 digits) |
300...750 V | 1 V | ±(3% m.v. + 2 digits) |
- frequency range: 45...65 Hz
The acronym „m.v.” stands for a „measured reference value”
Electrical safety:
- type of insulation double, in acc. with EN 61010-1 and IEC 61557
- measurement category III 600 V (IV 300 V) in acc. EN 61010-1
- case protection rating in acc. EN 60529 IP6529: IP65
Other technical specifications::
- power supply of the meter NiMH 9.6 V - 2 Ah battery pack and power supply 12 V
- weight of the meter approx. 0,9 kg
- dimensions 200 x 180 x 77 mm
- display LCD segment display
- measurement results memory 990 cells, 11880 records
- transmission of measurement results USB
Complete device information | |
Manufacturer site: |
Sonel MIC-5001 Insulation Resistance Meter
- Brand: Sonel S.A.
- Model: MIC-5001
- Product Number: WMGBMIC5001
- Availability: 2 to 14 days order processing
-
0.00€
Tags: Sonel, MIC-5001, Insulation, Resistance, Meter