Possible measurements:
- earth resistance measurment with 3-pole,4-pole method,
- earth resistance measurement without disconnecting measured earths (using clamp),
- continuity of equipotential bondings and protecting conductors
- two clamps earth resistance measurement without auxiliary test probs,
- earth resistivity measurement,
Earth resistance measurement - fall of potential method with clamps
It allows to take the measurements of:
- earth resistance using auxiliary electrodes,
- earth resistance using auxiliary electrodes and clamp (for measurements of multiple earth)
- earth resistance using double clamps (for measurement of earthing when it is impossible to use auxiliary electrodes),
- ground resistivity (Wenner method),
- measurement of continuity of equipotential bondings and protective conductors (meeting the requirements of IEC 60364 - 6-61:2000 section 6.12.2) with auto-zero function – with current 200 mA.
Additionally:
- measurement of resistance of auxiliary electrodes R S and R H ,
- measurement of interference voltage,
- measurement of interference frequency,
- measurement in the presence of interference voltage in the power network with frequency 50 Hz, 60 Hz
- selection of maximum measuring voltage (25 V and 50 V)
- introducing the distance between the electrodes for the resistivity in metres (m),
- memory of 990 measurements (10 banks of 99 cells each),
- calibration of clamp used,
- real time clock (RTC),
- data transmission to the computer (USB, wireless),
- indication of battery state.
Electric security:
- type of insulation: double, according to EN 61010 - 1 and IEC 61557
- measurement category: CAT IV 300 V acc. to EN 61010 - 1
- protection class acc. to EN 60529: IP54
Rated operational conditions:
- operation temperature: -10...+50°C
- storage temperature: -20...+70°C
- humidity: 20...80%
Other technical data:
- LCD display: graphic, backlighted
- interface: USB, wireless
- number of measurements carried out of set of batteries: > 500
- warranty: 24 months
Measurement of interference voltage
Range | Resolution | Accuracy |
0...100 V | 1 V | ±(2% m.v + 3 digits) |
- singnalling overvoltage 24 V or 40 V rms
- measurement for DC and AC 45…65 Hz,
Range | Resolution | Accuracy |
0,00...19,99 Ω | 0,01 Ω | ±(2% m.v. + 2 digits) |
20,0...199,9 Ω | 0,1 Ω | |
200...1999 Ω | 1 Ω | |
2,0k...9,99 kΩ | 0,01 kΩ | ±(5% m.v. + 4 digits) |
10,0k...19,9 kΩ | 0,1 kΩ |
- measurement current: under short circuit >200 mA,
- voltage on open terminals: selectable <25 V AC or <50 V AC,
- frequency of measurement current: 125 (for networks 50 Hz) or 150 Hz (for 60 Hz),
Range | Resolution | Accuracy |
0,00...19,99 Ω | 0,01 Ω | ±(2% m.v. + 2 digits) |
20,0...199,9 Ω | 0,1 Ω | |
200...1999 Ω | 1 Ω | |
2,0k...9,99 kΩ | 0,01 kΩ | ±(5% m.v. + 2 digits) |
10,0k...19,9 kΩ | 0,1 kΩ |
- voltage on open terminals: <24 Vrms but >4 Vrms,
- measurement current: under short circuit >200 mA,
- frequency of measurement current: 125 (for networks 50 Hz) or 150 Hz (for networks 60 Hz), possible choice of measurement frequency in menu,
- auto-zero function measurement leads
Measurement of resistance of auxiliary electrodes R H and R S
Range | Resolution | Accuracy |
0...999 Ω | 1 Ω | ±(5% (R S +R E +R H ) + 8 digits) |
1,00k...9,99 kΩ | 0,01 kΩ | |
10,0k...19,9 kΩ | 0,1 kΩ |
Range | Resolution | Accuracy |
0,00...19,99 Ω | 0,01 Ω | ±(8% m.v. + 3 cyfry) |
20,0...199,9 Ω | 0,1 Ω | |
200...1999 Ω | 1 Ω |
- voltage on open terminals: selectable <25 V AC or <50 V AC,
- measurement current: under short circuit > 200 mA,
- frequency of measurement current: 125 (for networks 50 Hz) or 150 Hz (for 60 Hz),
Measurement of multiple earth resistance with using double clamps
Range | Resolution | Accuracy |
0,00..19,99 Ω | 0,01 Ω | ±(10% m.v. + 3 digits) |
20,0...149,9 Ω | 0,1 Ω | ±(20% m.v. + 3 digits) |
- frequency of measurement current 125 (for networks 50 Hz) or 150 Hz (for networks 60 Hz)
Range | Resolution | Accuracy |
0,0...199,9 Ωm | 0,1 Ωm |
depending on measurement
accuracy R E with 4p method, but not less than ±1 digit |
200...1999 Ωm | 1 Ωm | |
2,00k...19,99 kΩm | 0,01 kΩm | |
20,0k...99,9 kΩm | 0,1 kΩm | |
100k...999 kΩm | 1 kΩm |
L – distance between probes: 1...50 m
Complete device information | |
Manufacturer site: |
Sonel MRU-120 Earth Resistance and Resistivity Meter
- Brand: Sonel S.A.
- Model: MRU-120
- Product Number: WMGBMRU120
- Availability: 2 to 14 days order processing
-
0.00€
Tags: Sonel, MRU-120, Earth, Resistance, Resistivity, Meter